Skip to content
Beaconby Winda
Fact

Corrosion under insulation (CUI), explained

·6 sources

Corrosion under insulation (CUI) happens when water gets past damaged cladding and the insulation holds it against the steel, so wall loss can grow out of sight until a leak. This film shows where the water comes from, why heat and shutdowns matter, and how inspectors find it.

By , Editor, with ·Checked

16:9 · 1:51 · English subtitles on YouTube · transcript below (PT1M51S) · Read the explainer

Transcript

Insulation keeps the heat in. It can also hold water against the steel, out of sight. This is corrosion under insulation, or CUI.21

Water comes from rain, sprinkler systems, cooling towers or condensation, and gets in wherever the cladding fails: a failed joint seal, a dent, a panel not refitted after maintenance.32

Inside, it runs to the low points. In the field, damage is often found at the six o'clock position.23

Fibrous insulation, such as mineral wool, soaks it up and holds it against the metal, with air close by.2

That is all steel needs. At an anode, iron leaves the metal and gives up electrons. They travel through the wall to a cathode, where oxygen and water consume them.4

Heat keeps it going. In 2011 the UK safety regulator rated thirty to a hundred and twenty degrees Celsius the most critical range; older pipework was at risk even when cold, and shutdowns put hot lines back at risk.2

And under the cladding, wall loss can grow unseen until a leak.21

So inspectors cut small windows where damage is most likely, or screen through the insulation with pulsed eddy current, guided waves or radiography.235

Offshore, in 2018, exhaust piping under insulation blankets was found corroded through.6

Corrosion under insulation. Read more in the Beacon Library.2

Sources

  1. 1.2025 Publications Catalog, entry for RP 583, Corrosion Under Insulation and Fireproofing (scope as API describes it) · American Petroleum Institute (API)
  2. 2.Corrosion under insulation of plant and pipework, semi-permanent circular SPC/TECH/GEN/18, issued 1 March 2011 (archived copy; the live page no longer exists) · UK Health and Safety Executive ·
  3. 3.Cao, Pojtanabuntoeng, Esmaily, Thomas, Brameld, Amer and Birbilis, A Review of Corrosion under Insulation: A Critical Issue in the Oil and Gas Industry, Metals 12(4), 561, 2022 · Metals (MDPI), via MIT DSpace ·
  4. 4.Forms of Corrosion · NASA Kennedy Space Center, Corrosion Engineering Laboratory
  5. 5.Cawley, Guided waves in long range nondestructive testing and structural health monitoring: principles, history of applications and prospects, NDT & E International 142, 103026, 2024 · NDT & E International (open access, CC BY 4.0) ·
  6. 6.Safety Bulletin No. 013: Severe Corrosion Found Under Insulation · Bureau of Safety and Environmental Enforcement ·